Automatic sliding door DataCenter RackMatic
REF: MP012
Specifications
  • DataCenter composed of 19 "rack cabinets, 42U and 800x1000mm base (width x depth).
  • Compatible with 19 "ESTI rack standards.
  • In the rear part of the cupboard there is a double-leaf perforated (grid) metal door. The back of the cabinet is the outside of the DataCenter. This door has a key lock.
  • There is no door in the front part of the cabinet. The pairThe front of the closet is accessed from the inner central corridor of the DataCenter. No door is required to facilitate access and because there is the option of installing the sliding door to block access to the entire DataCenter.
  • The couple of closets are joined frontally by the ceiling of the corridor. The aisle width (roof) is 1200mm. The corridor ceiling is supplied with each pair of cabinets. Through the roof you canco. It does not require a key but to know the security code for the automatic opening of the door.
More info
PVP
2,204.98
Price including VAT: 2,204.98
PVD
1,768.14
2 years
warranty
14 days
returns
100%
safe

Out of stock

We will notify you when it is back in stock.
More info
Specifications
  • DataCenter composed of 19 "rack cabinets, 42U and 800x1000mm base (width x depth).
  • Compatible with 19 "ESTI rack standards.
  • In the rear part of the cupboard there is a double-leaf perforated (grid) metal door. The back of the cabinet is the outside of the DataCenter. This door has a key lock.
  • There is no door in the front part of the cabinet. The pairThe front of the closet is accessed from the inner central corridor of the DataCenter. No door is required to facilitate access and because there is the option of installing the sliding door to block access to the entire DataCenter.
  • The couple of closets are joined frontally by the ceiling of the corridor. The aisle width (roof) is 1200mm. The corridor ceiling is supplied with each pair of cabinets. Through the roof you canco. It does not require a key but to know the security code for the automatic opening of the door.

More info

RackMatic modular DataCenter consisting of 19 "rack cabinets, 42U RackMatic modular DataCenter consists of the following parts:
  • Rack cabinets of 19 "of 42U Each 19" rack cabinet have a size of 800x1000mm (width x depth). The cabinets are supplied in pairs. Each pair of cabinets is joined by the ceiling of the corridor. The cabinets are joined laterally with the following ones, creating a DataCenter witha central corridor. The cabinets are the references #MP01 and #MP02.
  • Gateway to the DataCenter. It is the access door to the central corridor of the DataCenter. It is a sliding door that can be manual (reference #MP11) or automatic/motorized (reference #MP12). The use of the door is optional and is only necessary to block access to the datacenter. If one of the corridor openings of the DataCenter is against a paired, only one door will be needed. If the DataCenter has the corridor open at both ends, 2 doors will be needed.
Differences between #MP01 and #MP02

Both references are a pair of 19 "rack cabinets, height 42U and base size of 800x1000mm.The difference is in the lateral connection with the next pair of cabinets or with the sliding door.According to the location of the closet in the DataCenter, mustAcquire #MP01 or #MP02. The criteria would be:
  • #MP01: The couple of cabinets that goes to the ends of the DataCenter. One of the sides of the couple of cabinets are ready to fix the rail of the sliding door, in case you want to install sliding door. The other part of the couple of closets is ready to be fixed to another couple of closets. In addition, the lateral that would correspond to the external partr of the DataCenter, has side covers, which close the DataCenter.
  • #MP02: The couple of cabinets that goes in the central part or the DataCenter. This pair of closets is ready to join another pair of closets on both sides.
Examples of configurations
  • DataCenter with 4 19 "rack cabinets (2 pairs) and 2 manual doors at both ends: 2 #MP01 and 2 #MP11.
  • DataCenter of 4 wardrobes 19 "rack (2 pairs) and 1 manual door on one end: 2 #MP01 and 1 #MP11.
  • DataCenter with 4 19 "rack cabinets (2 pairs) without doors: 2 #MP01.
  • DataCenter of 6 19 "rack cabinets (3 pairs) and 2 manual doors on both ends: 2 #MP01, 1 #MP02 and 2 #MP11.
  • DataCenter with 8 19 "rack cabinets (4 pairs) and 2 automatic doors at both ends: 2 #MP01, 2 #MP02 and 2 #MP12.
  • DataCenter of 10 rack cabinets19 "(5 pairs) and 2 automatic doors at both ends: 2 #MP01, 3 #MP02 and 2 #MP12.
  • DataCenter with 12 rack 19 "cabinets (6 couples), 1 automatic door at one end and 1 manual door at the other end of the aisle: 2 #MP01, 4 #MP02, 1 #MP12 and 1 #MP11.
  • DataCenter with 14 19 "rack cabinets (7 pairs) without doors at the ends of the aisle: 2 #MP01 and 5 #MP02.
DataCenter Specifications
  • DataCenter composed of 19 "rack cabinets, 42U and 800x1000mm base (width x depth).
  • Compatible with 19 "ESTI rack standards.
  • In the rear part of the cupboard there is a double-leaf perforated (grid) metal door. The back of the cabinet is the outside of the DataCenter. This door has a key lock.
  • There is no door in the front part of the cabinet. The pairThe front of the closet is accessed from the inner central corridor of the DataCenter. No door is required to facilitate access and because there is the option of installing the sliding door to block access to the entire DataCenter.
  • The couple of closets are joined frontally by the ceiling of the corridor. The aisle width (roof) is 1200mm. The corridor ceiling is supplied with each pair of cabinets. Through the roof you canco. It does not require a key but to know the security code for the automatic opening of the door.
  • Gross Weight: 102.0 kg
  • Number of packages: 7

Technical terms

  • RACK 19
  • Rack unit (U)
RACK 19
A rack is a metal support designed to house electronic, computer and communications equipment. The measures for the width are normalized to be compatible with most equipment manufacturers. They are also called racks, cabinets, cabinets or closets. Each column has holes at regular intervals called U rack units (Pictured: 4) grouped in threes. The height (Pictured:5) of the racks is standardized and external dimensions of 200 mm by 200 mm. Being normal that from 4U to 46/47U height width types (Pictured: 7). Standard 600 mm or 800 mm Types of background (Pictured: 6) The depth of the frame is not standardized, as this flexibility is granted (Pictured: 8) to the equipment. The most common are: - 450 mm - 600 mm - 800 mm - 900 mm - 1000 mm - 1200 mm Type 19-inch rack can find various types of 19-inch rack. Rack Mural (Pictured: 2): Used to accommodate electronic network. They are the smallest and are anchored to wall. Rack Pie (Pictured: 1): They are used primarily for servers, UPS and network electronics. Open Rack (Pictured: 3): Open Rack Racks are available only modelsstructure, eliminating doors and other accessories.